Crystal Auto biochemistry analyzer (300 T/H)
Features:
1. Fully automatic, Discrete, Random access
2.300 T/H, 45 reagent position, 60 sample position and 120cuvettes.
3. Refrigerated reagent tray, 24 hour working.
4. Reversed optics and imported photo sensor, ensuring the precision of detection results.
|
Overall Performance |
Model |
BIOBASE-CRYSTAL |
||||
|
Type |
discrete, fully automatic |
|||||
|
Throughput |
300T/H |
|||||
|
Analysis Method |
End-point, Fixed-time,Rate |
|||||
|
Programming Items |
programmable for any test items |
|||||
|
Certification |
CE, FDA, ISO9001, ISO14001, ISO13485 |
|||||
|
Sample unit |
Sample Settings |
60 sample positions, including calibration, quality control and emergency, primary tubes and serum is available |
||||
|
Sample Volume |
2ul ~50ul (0.1ul stepping) |
|||||
|
Sample Probe |
Having liquid level induction function, ensuring the accuracy of adding sample |
|||||
|
Probe cleaning |
Automatic washing both interior and exterior |
|||||
|
Analysis Items |
analyzing maximally 45 items at the same time |
|||||
|
Reagent unit |
Reagent Position |
45 low-temperature refrigerated reagent position |
||||
|
Reagent Volume |
R1:25~300ul, R2:10~150ul (1ul stepping), supporting reagent from different countries |
|||||
|
Temperature Control |
continuous 2C~8Ccooling within 24 hours |
|||||
|
Reagent Probe |
Having liquid level induction function, ensuring the accuracy of adding reagent. Inventory checking |
|||||
|
Probe cleaning |
Automatic washing both interior and exterior |
|||||
|
Reaction unit |
Reaction Time |
10 minutes |
Temperature Control |
37C±0.1C |
||
|
Cuvettes |
120 independent reaction cuvettes (optical path length 6mm) |
|||||
|
Stirrer |
after injecting reagent and sample, blending immediately |
|||||
|
Cleaning |
automatic water cleaning and drying system |
|||||
|
System Adjustment |
System can record the blank value and get more accurate result by deducting blank base value of each cuvette |
|||||
|
Optical System |
Light Source |
12V/30W halogen-tungsten lamp, 2000 hours |
||||
|
Receiver |
8 precision photo receivers |
|||||
|
Wavelength Range |
340,405,450,510,546,578,630,700mm |
|||||
|
Calibration and QC |
Calibration |
one-point,multi-point |
Linear Range |
0.000~2.500Abs |
||
|
Quality Control |
Inserting quality control at random.6 quality controls can be reached with one item |
|||||
|
Software |
Emergency Function |
emergency sample can be placed in the sample tray at any time |
||||
|
Software |
Windows 2000 or Windows XP or above, sample and easy to operate |
|||||
|
Data Processing |
Having reaction curve detection and data display function in the whole process |
|||||
|
Others |
Power Supply |
AC220V+22V 50Hz+1Hz |
||||
|
Dimension |
1020mm×830mm×1200mm (W*D*H) |
|||||
|
Weight |
150kg |
|||||
Accessories:
|
Name |
Unit |
Quantity |
|
Sample cup |
One |
1 |
|
Cuvettes |
Pack(120 units) |
1 pack |
|
Reagent Probe |
One |
1 |
|
Sample Probe |
One |
1 |
|
Mixer |
One |
1 |
|
Fuse wire |
One |
1 |
|
Halogen lamp |
One |
1 |
Bstar300 superconductive 3.0T
Gynecology operation bed
Bladdar Scanner
Raecho Laptop Color Doppler
Lower Limbs Instrument
Upper Limbs Instrument
Female sterilization surgery
Ophthalmic Surgical Instrument Package
DC-N2 Color Doppler
S30 Color Doppler Ultrasound
S40 Color Doppler Ultrasound
BC5150 Hematology Analyzer
DC-70 Color Doppler Ultrasound
Ebola Protection Clothes
DC-7 Echocardiograph
Medical Incinerator
PLX-101D Radiology
E30 Color Doppler
Qbit9 Supreme
Qbit 7 Color Doppler
MRI system 0.4t